Adobe Format of this Page  |   Home  |   Product Summary  |   Where to Buy   |   Instruction Sheet (Adobe)

 
TIME DELAY RELAYS
TD-8 Series DIP-Switch Digital-Set Programmable Plug-in
Multi-Function & Single-Function Versions


  • Available as either a multifunction version with 16 functions built-in or as individual function versions
  • DIP-Switches for accurate digital set of time delay (multi- & single-function) & selection of function (for multi-function only)
  • Programmable delay of 100ms - 1,023 hours (multi-function) or 100ms - 1,023 minutes (single-function)
  • Uses industry-standard 8 & 11 pin octal sockets
  • 10A DPDT output contacts
  • LED indicates relay status

 

 

 

 

 

 

 

 




































































** TIMING RANGE TABLE
Complete Product Number Using Two Digit Code From Below, i.e., TD-80222-40
Time Delay RangeCode
0.1 – 102.3 Sec.
1 – 1,023 Sec
10 – 10,230 Sec.
1 – 1,023 Min.
40
41
42
43

logo

800-238-7474
www.macromatic.com

TD-88122 TD-88122-side TD-80222
Multi-Function Multi-Function Single Function

The TD-8 series of time delay relays offer an easy and accurate way to select any time delay between 100ms & 1,023 hours. Programming is accomplished through the use of 10-position DIP-switches. This method provides a greater setting accuracy than is found on other units with an analog potentiometer. An LED indicates relay status.

The TD-8 series comes in two versions: a multi-function product with 16 functions built-in or a single function product.


Multi-Function

The TD-881 Series offers the digital-set accuracy of DIP-switch setting as well as the flexible programmability of a multi-function & multi-time range relay. These products provide an easy & accurate method to select any of 16 time delay functions and any time range between 100ms and 1,023 hours. This product can literally replace hundreds of different catalog numbers, thereby reducing inventory requirements.

Programming Function & Time Delay

chart
chartProgramming is accomplished through the use of two 10-position DIP-switches (see drawings at right). Switches A-D of the left-mounted DIP-switch are used to select a function. Switches E-K of the same DIP-switch are used to select the time base. A convenient chart is on the side of the relay to clearly illustrate how to set both the function & time base.

The right-mounted 10-position DIP-switch is used to select the time delay within the time base selected with switches E-K from the first DIP-switch. Each position on the second DIP-switch is marked with a binary time increment. The required delay is selected by moving the switch of each increment to the ON position & adding their corresponding values (see right). Note that dual mode products can either have the same or different ON & OFF times.

FUNCTION *INPUT
VOLTAGE
PRODUCT
NUMBER
WIRING/
SOCKETS
MULTI-FUNCTION
(16 Field-Selectable
Functions in One Unit)

Single Mode

  • On Delay
  • Interval On
  • Flasher (OFF 1st)
  • Flasher (ON 1st)
  • Off Delay
  • Single Shot
  • Watchdog
  • Single Shot (Trailing Edge)
  • Triggered On Delay

Dual Mode

  • Repeat Cycle (OFF 1st)
  • Repeat Cycle (ON 1st)
  • Delayed Interval
  • Triggered Delayed Interval
  • On Delay/Off Delay
  • Single Shot-Flasher
  • On Delay/Flasher
120V AC/DC

12V AC/DC

24V AC/DC

240V AC
TD-88122

TD-88126

TD-88128

TD-88121
11 PIN OCTAL
70170-D
wiring diagram
DIAGRAM 121

* Click here for a Description of Functions.

Click here for Sockets & Accessories.

Single-Function

chartThe TD-8 Series time delay relays offer an easy & accurate method to select any time delay between 100ms & 1,023 minutes. Programming is accomplished through the use of a 10-position DIP-switch. Each position is marked with a binary time increment. The required delay is selected by moving the switch of each increment to the ON position & adding their corresponding values (see examples at right). This method provides a greater setting accuracy than is found on other units with an analog potentiometer. An LED indicates relay status.






FUNCTION *

INPUT
VOLTAGE
50/60Hz.
PRODUCT NUMBER
Complete Product Number
Using 2 Digit Code From
Table at Left

WIRING/
SOCKETS
ON DELAY120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TD-80222-**
TD-80226-**
TD-80228-**
TD-80221-**
8 PIN OCTAL
70169-D
 
wiring diagram

DIAGRAM 1
INTERVAL ON120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TD-80522-**
TD-80526-**
TD-80528-**
TD-80521-**
REPEAT CYCLE
(OFF Time First Followed By ON Time and Repeating)
120VAC/DC
12V AC/DC
24V AC/DC
240V AC
TD-83122-**
TD-83126-**
TD-83128-**
TD-83121-**
REPEAT CYCLE
(ON Time First Followed By OFF Time and Repeating)
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TD-85122-**
TD-85126-**
TD-85128-**
TD-85121-**
OFF DELAY
Control Switch Trigger
120VAC/DC
12V AC/DC
24V AC/DC
240V AC
TD-81622-**
TD-81626-**
TD-81628-**
TD-81621-**
11 PIN OCTAL
70170-D

wiring diagram
DIAGRAM 2
SINGLE SHOT
Control Switch Trigger
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TD-81522-**
TD-81526-**
TD-81528-**
TD-81521-**

* Click here for a Description of Functions.

Click here for Sockets & Accessories.



APPLICATION INFORMATION DIMENSIONS
Voltage Tolerance: AC Operation: +10/-15% of nominal at 50/60 Hz.; DC Operation: +10/-15% of nominal.

Load (Burden): 2 VA

Setting Accuracy: +1% of set time or +50ms, whichever is greater.

Repeat Accuracy (Constant Voltage & Temperature): +0.1% of set time or +0.02 seconds, whichever is greater.

Reset Time: 0.04 Seconds

Output Contacts: 10A @ 240V AC/30V DC, 1/2HP @ 120/240V AC (N.O.),
1/3HP @ 120/240V AC (N.C.), B300 & R300

Life: Mechanical: 10,000,000 operations; Full Load: 100,000 operations

Temperature: -28o to 65o C (-18o to 150o F)

Insulation Voltage: 2,000 volts

Approvals:

c-ur-us.jpg  UL-socket.jpg


dimension_img


Inches (Millimeters)

        Revised:  07/08