Single-Probe Plug-In

May not be exact product – for reference only.

LCP2B100F60

Lead Time: 

7 Days

Function/Configuration

Single Probe Pump Down

Control Voltage:

120V AC

Fixed Time delay

60s

Sensitivity range:

Sensitivity Range: 4.7K – 100K Ohms

$102.08

Description of Function

5V DC Pulsed

Description of Function

Product Overview

Features:

Controls Level of Conductive Liquids in Pump Up (Fill) or Pump Down (Drain) Applications Probe is Pulsed with DC Voltage to Prevent Electrolysis Two Adjustable Sensitivity Ranges Input Voltages of 24, 120 & 240V

Enclosure Style:

Plug-in case utilizing industry-standard 8 pin octal sockets
Configuration / Contact Rating:
SPDT • 10A @ 240V AC/7A @ 28V DC, 1/4HP @ 120V AC (N.O.)
Application Information:
Voltage Tolerance: AC Operation: +10/-15% of nominal at 50/60 Hz. Load (Burden): 2 VA Indicator LEDs: Green ON with Input Voltage applied; Red Flashing during timing; Red ON when relay energized. Probe Voltage: 5V DC Pulsed Response Time: Pick-up: Fixed per value shown under “Function” in table above; Drop-out: 500ms Output Contacts: 10A @ 240V AC/7A @ 28V DC, 1/4HP @ 120V AC (N.O.) Life: Mechanical: 10,000,000 operations; Full Load: 100,000 operations Temperature: -28° to 65° C (-18° to 149° F)
Approvals:
UL #: E109466

Operations

Pump Up (Fill): When the liquid level falls below the probe, a fixed time delay begins and the LED flashes Red. This time delay prevents rapid cycling of the output relay and its load. At the end of the time delay, the output relay energizes and the LED is Red ON. The pump is ON to fill the tank. The relay remains energized until the liquid level rises and touches the probe. The output relay de-energizes, turning off the pump, and remains de-energized and the LED is Green ON until the liquid level falls below the probe. Pump Down (Drain): When the liquid level rises and touches the probe, a fixed time delay begins and the LED fl ashes Red. This time delay prevents rapid cycling of the output relay and its load. At the end of the time delay, the output relay energizes and the LED is Red ON. The pump is ON to drain the tank. The relay remains energized until the liquid level falls below the probe level. The output relay de-energizes, turning off the pump, and remains de-energized and the LED is Green ON until the liquid level rises and touches the probe. If the container is non-conductive or insulated, an additional probe must be installed as the COM connection where it will always be submerged.

Product Reviews

Do you have experience with this product? Leave us a review!
Add a review
LCP2B100F60 LCP2B100F60
Overall rating*
0/5
* Rating is required
Product Rating*
0/5
* Rating is required
* Answer is required
Your review
* Review is required
Name
* Name is required
* Please confirm that you are not a robot
0.0
Based on 0 reviews
5 star
0%
4 star
0%
3 star
0%
2 star
0%
1 star
0%
0 of 0 reviews

Sorry, no reviews match your current selections