ISEUR1
Lead Time: In Stock
Description Of Function
Each ISE Series relay consists of an intrinsically safe input and a corresponding electromechanical relay output. There is one bi-color LED for status indication. With input voltage applied, the LED will be ON (Green) to indicate power is applied. When the input device from the hazardous area is closed, the output relay is energized and the LED is ON (Orange). When the input device opens, the output relay will de-energize and the LED will be ON (Green).
Function Chart
Product Overview
Features
- Approved for use in these hazardous environments:
- Class I, Div 1 (Zones 0 and 1 Canada), Groups A,B,C,D
- Class II, Div 1 (Zones 20 and 21 Canada), Groups E,F,G
- Class III, Div 1
- 1-Channel
- 5A relay output
- Universal input voltage of 102-132V AC & 10-125V DC
- LED status indicator
- UL913 8th Edition
Enclosure Style
Compact 17.5mm wide enclosure for both DIN-rail & panel-mounting with four screws
Configuration / Contact Rating
- SPST-NO (Form A)
- 3A Resistive @ 125V AC @ 60oC & 30V DC Resistive, Pilot Duty Rating D300
- 5A Resistive @ 125V AC @ 40oC & 30V DC Resistive, Pilot Duty Rating D300
Application Information
- Voltage Tolerance: 102-132V AC (50/60Hz.) & 10-125V DC
- Load (Burden): 2VA Maximum
- Response Times: < 50ms
- Mounting: Mounts on 35mm DIN-rail or panel-mounted with two #8 screws when DIN-rail clips are fully extended from under the enclosure.
- Indicator LED: ON (Green) - Input voltage; ON (Orange) - Input closed and relay energized
- Output Contacts: SPST-NO (Form A) 3A Resistive @ 125V AC @ 60oC & 30V DC Resistive; 5A Resistive @ 125V AC @ 40oC & 30V DC Resistive; Pilot Duty Rating D300
- Life: Electrical: 50,000 Closures @ Full Load AC ; Mechanical: 5 Million Closures @ No Load
- Temperature: -28° to 60° C (-18° to 140° F)
Operation
Each ISE Series relay consists of an intrinsically safe input and a corresponding electromechanical relay output. There is one bi-color LED for status indication. With input voltage applied, the LED will be ON (GREEN) to indicate power is applied.
Standard Operation
When the input device from the hazardous area is closed, the output relay is energized and the LED is ON (ORANGE). When the input device opens, the output relay will de-energize and the LED will be ON (GREEN).
Inverted Operation (V-suffix)
When the input device from the hazardous area is open, the output relay is energized and the LED is ON (ORANGE). When the input device closes, the output relay will be de-energized and the LED will be ON (GREEN).
File Downloads
-
Digital Catalog
-
901-0000-329 Installation Instructions ISE Series
Instruction Sheet
-
ISE eCAD Package
CAD Drawing