PMPU-FA12X Series

PMPU-FA12X

Lead Time: 7 Days

$171.09 (USD) / EACH

Description Of Function

Image removed.When the proper 3-phase line voltage is applied to the unit and the phase sequence (rotation) is correct, the relay is energized after the Restart Delay is completed. Any one of five fault conditions will de-energize the relay after a delay. As standard, re-energization is automatic upon correction of the fault condition. A multi-color status LED indicates normal condition and also provides specific fault indication to simplify troubleshooting (see right).

Function Chart

Product Overview

Features
  • Protects against phase loss, phase reversal, phase unbalance, undervoltage, overvoltage & rapid cycling
  • Universal voltage range of 190-500V—greater range that covers more global applications
  • True RMS voltage measurement ensures accurate sensing across more applications
  • Retains fault indication and continues monitoring all voltages even with a lost phase
  • Full fault indication on top of unit for easy troubleshooting
  • 5A DPDT output provides isolated contact for alarm circuits  | Learn More
Enclosure Style

Plug-in case utilizing industry-standard 8 pin octal sockets

Configuration / Contact Rating
  • DPDT
  • 5A @ 277V AC / 5A @ 30V DC;
    1/3HP @ 120/240V AC, B300 Pilot Duty
Application Information
  • Load (Burden): Less than 40 VA
  • Minimum/Maximum Voltage: 156-550V, all 50/60Hz. +5#%
  • Reset: Automatic upon correction of fault.
  • Output Contacts: 5A @ 277V AC / 30V DC;
    1/3HP @ 120/240V AC; B300 Pilot Duty
  • Life: Mechanical: 10,000,000 operations, Full Load: 100,000 operations
  • Temperature: -28° to 65° C (-18° to 149° F)
Approvals

Operation

When the proper three-phase line voltage is applied to the unit and the phase sequence (rotation) is correct, the relay is energized after the Restart Delay is completed.  Any one of five fault conditions will de-energize the relay.  Re-energization of the relay is automatic upon correction of the fault condition.  A bi-color status LED indicates normal condition and also provides specific fault indication to simplify troubleshooting.

You May Be Interested in These Other Products

  • Function: Delayed interval (switch trigger)
  • Timing Range: Multi-range (16): 0.05 seconds to 100 hours
  • Timing Range 2: Multi-range (16): 0.05 seconds - 100 hours
  • Timing Adjustment: Analog
  • Control Voltage: Universal: 24-240V AC and 12-125V DC
  • Output: 10A DPDT
  • Enclosure Type: Plug-in
  • Standard Modifications: None
  • Remote Potentiometer: None
  • Remote Potentiometer 2: None
$127.29
  • Function: Overcurrent AC only
  • Control Voltage: 120V AC
  • Output: 10A SPDT
  • Trip Delay: None
  • Enclosure Style: Plug-in
  • Current Range: 0.5 - 5A
  • Sensing Delay On Power: 0.1 - 10 seconds
$141.22
  • Control Voltage: 120V AC
  • Output: 4 Form C Contacts
  • Options: Standard (LED and Push-to-Test Included)
  • Terminal Configuration: Blade
$14.51