TR-5 Series (Dual F46)

TR-54621-07-04

Lead Time: 9 Days

$150.67 (USD) / EACH

Description Of Function

Upon application of input voltage, a preset delay begins (T1). At the end of the preset delay, the relay is energized. When the input voltage is removed, the relay contacts remain energized for a second, independently adjustable preset time (T2). At the end of the second preset time, the relay is de-energized. Voltage must be applied for a minimum of 0.1 second to assure proper operation. Any application of the input voltage during the time (T2) will keep the relay energized & reset T2. When input voltage is removed, the relay contacts remain energized for the full time (T2). No external trigger switch is required.

Function Chart

Product Overview

Features
  • Each unit has a single timing range
  • Choose from 11 separate timing ranges from 0.02 Seconds to 2 Hours
  • 10A DPDT output contacts (selected functions that are normally offered with 11 pin DPDT output are also available in 8 pin SPDT versions)
  • ON & OFF times on dual timer products are independently adjustable (contact Macromatic for information on ordering dual timer units with different ON & OFF time ranges)
  • Pilot Duty Rating
Enclosure Style

Plug-in case utilizing industry-standard 8 or 11 pin octal sockets

Configuration / Contact Rating
  • DPDT & SPDT
  • 10A @ 240V AC/30V DC, 1/2HP @ 120/240V AC (N.O.),1/3HP @ 120/240V AC (N.C.), B300 & R300
Application Information
  • Voltage Tolerance: AC Operation: +10/-15% of nominal at 50/60 Hz.; DC Operation: +10/-15% of nominal.
  • Load (Burden): 2 VA
  • Setting Accuracy:
    Maximum Setting (Adjustable): +5%, -0%;
    Minimum Setting (Adjustable): +0%, -50%.
    Fixed: +2% or 100ms, whichever is greater
  • Repeat Accuracy (Constant Voltage & Temperature): +1% or 50ms, whichever is greater
  • Reset Time: 0.1 Seconds
  • Output Contacts: 10A @ 240V AC, 8A @ 28V DC, 1/2HP @ 240V AC, 1/4HP @ 120V AC, B300 & R300
  • Life: Mechanical: 2,000,000 operations; Full Load: 100,000 operations
  • Temperature: -28° to 65° C (-18° to 149° F)

Operation

TR-5 Non-Programmable plug-in time delay relays are flexible and reliable. The most common timing functions are available in all standard input voltages. Each product is offered with a choice of time delay adjustment: on-board adjustable with a single timing range; fixed time delay; or remote adjustable. All dual-time functions such as repeat cycle or delayed interval have an option for independently selectable and adjustable ON & OFF times for ultimate flexibility. These products utilize industry-standard 8 & 11 pin octal sockets, and have 10A DPDT output contacts (selected functions that are normally offered with 11 pin DPDT output are also available in 8 pin SPDT versions).

You May Be Interested in These Other Products

  • Function: Overcurrent AC/DC
  • Control Voltage: 120V AC
  • Output: 10A SPDT
  • Trip Delay: None
  • Enclosure Style: Plug-in
  • Current Range: DC: 5 -100mA, 0.05 - 1A, and 0.5 - 10A ; AC: 3.5 - 70.7mA, 0.035 - 0.707A, and 0.35 - 7.707A
  • Sensing Delay On Power: 0.1 - 10 seconds
$146.64
  • Communication Platform: Modbus TCP
  • Monitored Voltage: 190-600V AC
  • Output: 5A SPDT
  • Protection: Phase Loss, Phase Reversal, Voltage Unbalance, Undervoltage & Overvoltage
  • Standard Modifications: Local Adjustment (PC1MDUL);
  • Enclosure Style: DIN-Rail
$550.08
  • Control Voltage: 120V AC
  • Output: 4 Form C Contacts
  • Options: Standard (LED and Push-to-Test Included)
  • Terminal Configuration: Blade
$14.51