TR-606 Series True Off Delay

TR-60621

Lead Time: 7 Days

$147.33 (USD) / EACH

Description Of Function

Upon application of input voltage, the relay is energized. When the input voltage is removed, the preset time begins. At the end of the preset time, the relay is de-energized. Voltage must be applied for a minimum of 0.1 second to assure proper operation. Any application of the input voltage during the preset time will keep the relay energized & reset the time delay. No external trigger switch is required.

Function Chart

Product Overview

Features
  • Each unit has 8 timing ranges built-in covering 0.1 seconds-30 minutes
  • Selecting a range is easy using a rotary switch (no math is required or DIP switches to set)
  • 10A output contacts can handle most pilot duty & fractional HP loads
Enclosure Style

Plug-in case utilizing industry-standard 8 pin octal sockets

Configuration / Contact Rating
  • DPDT
  • 10A @ 240V AC, 8A @28V DC, 1/2 HP @ 240V AC, 1/4HP@ 120V AC, B300 & R300
Application Information
  • Voltage Tolerance: AC Operation: +10/-15% of nominal at 50/60 Hz.; DC Operation: +10/-15% of nominal.
  • Load (Burden): 2 VA
  • Setting Accuracy: Maximum Setting (Adjustable): +5%, -0%; Minimum Setting (Adjustable): +0%, -50%.
  • Repeat Accuracy (Constant Voltage & Temperature): +1% or 50ms, whichever is greater
  • Reset Time: 0.1 Seconds
  • Output Contacts: 10A @ 240V AC, 8A @ 28V DC, 1/2HP @ 240V AC, 1/4HP @ 120V AC, B300 & R300
  • Life: Mechanical: 2,000,000 operations; Full Load: 100,000 operations
  • Temperature: -28° to 65° C (-18° to 149° F)

Operation

Upon application of input voltage, the output is energized. When the input voltage is removed, the time delay (t) begins. At the end of the time delay (t), the output is de-energized. Input voltage must be applied for a minimum of 0.5 seconds to assure proper operation. Any application of the input voltage during the time delay (t) will reset the time delay. No external trigger is required.

You May Be Interested in These Other Products

  • Function: Overcurrent AC/DC
  • Control Voltage: 120V AC
  • Output: 10A SPDT
  • Trip Delay: None
  • Enclosure Style: Plug-in
  • Current Range: DC: 5 -100mA, 0.05 - 1A, and 0.5 - 10A ; AC: 3.5 - 70.7mA, 0.035 - 0.707A, and 0.35 - 7.707A
  • Sensing Delay On Power: 0.1 - 10 seconds
$146.64
  • Communication Platform: Modbus TCP
  • Monitored Voltage: 190-600V AC
  • Output: 5A SPDT
  • Protection: Phase Loss, Phase Reversal, Voltage Unbalance, Undervoltage & Overvoltage
  • Standard Modifications: Local Adjustment (PC1MDUL);
  • Enclosure Style: DIN-Rail
$550.08
  • Control Voltage: 120V AC
  • Output: 4 Form C Contacts
  • Options: Standard (LED and Push-to-Test Included)
  • Terminal Configuration: Blade
$14.51