ARP Duplex Controllers

ARP024A8R

Lead Time: 7 Days

$157.48 (USD) / EACH

Description Of Function

In the initial OFF state, all three switches are open, the Duplex Pump Controller is in the LOAD 1 position, and both loads are off. No action happens with the Controller or either load when the OFF switch closes. When the LEAD Switch closes, LOAD 1 turns on. When the LAG Switch closes, LOAD 2 turns on. Both loads remain on as long as all three switches are closed. When the LAG Switch opens, LOAD 2 remains on because the Duplex Controller simulates the function of an auxiliary contact. When the LEAD Switch opens, LOAD 1 remains on for the same reason. When the OFF Switch opens, both LOAD 1 and LOAD 2 are turned off simultaneously because all voltage is removed to both loads. The Duplex Controller toggles to the LOAD 2 position. The entire cycle is then repeated, but with LOAD 2 energized first followed by LOAD 1.

These products protect against failure of the OFF or LEAD Switches

Function Chart

ARP

Product Overview

Features
  • Combines functions of alternating relay, control relay & auxiliary contacts in one unit - saves money
  • Offers Sequence On - Simultaneous OFF (S.O.S.O.) Operation with three float switch inputs
  • Protects against failures of both OFF & LEAD switches
  • Low profile selector switch for normal alternation or to lock either load to be ON first
  • 2 LEDs indicate load to energize first
Enclosure Style

Plug-in case utilizing industry-standard 8 pin octal sockets

Configuration / Contact Rating
  • DPDT Cross-Wired
  • 5A @ 120V AC/24V DC, B300
Application Information
  • Voltage Tolerance: AC Operation: +10/-15% of nominal at 50/60 Hz.; DC Operation (12 & 24V only): +10/-15% of nominal.
  • Load (Burden): Less than 3 VA
  • Indicator LEDs: Two LEDs marked LOAD 1 and LOAD 2
  • Selector Switch: ALTERNATE, LOAD 1; LOAD 2
  • Output Contacts: 10A @ 240V AC/24V DC, 1/2HP @ 120/240V AC (N.O.), 1/3HP @ 120/240V AC (N.C.)
  • Life: Mechanical: 10,000,000 operations; Full Load: 100,000 operations
  • Temperature: -28o to 65o C (-18o to 149o F)
Approvals

Operation

In the initial OFF state, all three switches are open, the Duplex Pump Controller is in the LOAD 1 position, and both loads are off (see Diagram below). No action happens with the Controller or either load when the OFF switch closes. When the LEAD Switch closes, LOAD 1 turns on. When the LAG Switch closes, LOAD 2 turns on. Both loads remain on as long as all three switches are closed. 

ARP Duplex Controllers Operation Schematic

When the LAG Switch opens, LOAD 2 remains on because the Duplex Controller simulates the function of an auxiliary contact. When the LEAD Switch opens, LOAD 1 remains on for the same reason. When the OFF Switch opens, both LOAD 1 and LOAD 2 are turned off simultaneously because all voltage is removed to both loads. The Duplex Controller toggles to the LOAD 2 position. The entire cycle is then repeated, but with LOAD 2 energized first followed by LOAD 1.

These products protect against failure of the OFF or LEAD Switches—if one or both of these switches fail to close in sequence, the two LOADS will be energized when the LAG switch closes. In addition, both LOADS are turned off simultaneously when the LAG switch opens.

These products have a three position selector switch. This provides the option to alternate the two loads as normal or select which load always comes on first when the LEAD switch closes. In either case, a load that has fewer hours of operation than the other load could be used more often to eventually balance the run time of both loads. The low-profile selector switch prevents any accidental changes in status.

You May Be Interested in These Other Products

  • Function Configuration: Single Channel 11 Pin DPDT
  • Control Voltage: 120V AC
  • Output: 7A DPDT
  • Sensitivity Range: 1K to 250K ohms
  • Mount: Plug-in
$135.74
  • Communication Platform: None
  • Monitored Voltage: 102-138V AC
  • Output: 10A SPDT
  • Protection: Phase Loss, Phase Reversal, Voltage Unbalance, Undervoltage & Overvoltage
  • Standard Modifications: None
  • Enclosure Style: Plug-in